Sell 2,000 kVA Transformer Equipment in Virginia

Quick answerTo sell 2,000 kVA transformer equipment, send Virginia Transformer Buyers a clear nameplate photo, overall photos, location, quantity and condition notes. We buy three-phase pad-mount, unit substation and substation transformers across Virginia, including used and new-surplus units. We pay attention to voltage configuration, cooling rating, connection arrangement and loading access. Failed units are reviewed case by case, and PCB status must be disclosed and documented.
Pad-mount step-up transformer beside an inverter at a solar farm

A 2,000 kVA transformer sits in a substantial three-phase equipment class: large enough for plant distribution, data center power blocks and solar or battery project connections. We buy this size in oil-filled, dry-type and cast resin construction, including equipment removed from service and unused project surplus.

The rating alone does not describe the equipment. A dead-front pad-mount with a 480Y/277 secondary is a different installation fit from a unit substation with bus connections. Our transformer size guide organizes equipment by rating, but the nameplate and connection photos tell us what you actually have.

01What the 2,000 kVA rating tells a buyer

A 2,000 kVA rating equals 2 MVA of apparent power. It is not automatically 2,000 kW of usable real power; that relationship depends on power factor and operating conditions. For a buyer, the rating establishes the capacity class, while voltage, impedance, cooling and physical configuration determine suitability for another installation.

Check whether 2,000 kVA is the base rating or one step in a multiple-rating nameplate. An oil-filled transformer may list ONAN and ONAF ratings, with higher capacity tied to forced-air cooling. Photograph the complete rating block and any fan-control information. We need to distinguish a base-rated 2,000 kVA unit from equipment that reaches that rating only with fans operating.

02Pad-mount, unit substation and substation configurations

For three-phase pad-mount transformers, send photos of the cabinet, doors and accessible connection compartments. Dead-front or live-front construction, loop-feed or radial-feed arrangements, and secondary terminal layout help identify the installation fit. Have qualified personnel handle access to electrical compartments; do not open energized equipment for photographs.

For unit substation equipment, show how the transformer connects to primary equipment and secondary switchgear. Throat dimensions, bus connections and close-coupled arrangements matter because replacement equipment must physically align. For substation transformers, photograph the bushings, terminal arrangement, radiators and accessories. Tell us whether the sale includes only the transformer or also associated equipment.

Full-load amps for a 2,000 kVA three-phase transformer

The amp table on this page uses the standard formula Amps = kVA × 1,000 ÷ (1.732 × line-to-line volts). Match the voltage on your nameplate to read the rated full-load current of each winding.

2,000 kVA three-phase full-load current
Winding voltageFull-load amps
208 V5,551
240 V4,811
480 V2,406
600 V1,925
2,400 V481
4,160 V278
12,470 V92.6
13,200 V87.5
13,800 V83.7
23,000 V50.2
34,500 V33.5

03Voltage combinations and full-load current

A 2,000 kVA distribution transformer may have a medium-voltage primary such as 12,470, 13,200, 13,800 or 34,500 volts, paired with a secondary such as 480Y/277 volts. Other combinations serve different plant and project requirements. Copy the full designation: 12470GrdY/7200 conveys information that simply writing “12 kV” leaves out. Include phase, frequency, winding connections, tap positions and impedance.

Use the amp table on this page to compare current at different voltages. For three-phase equipment, full-load current is I = kVA × 1,000 ÷ (√3 × line-to-line volts). One example: 2,000 × 1,000 ÷ (√3 × 480) is approximately 2,406 amps. This is rated full-load current, not a specification for protective devices or conductors. The kVA and full-load amps guide explains the relationship further.

04Confirm the size from the complete nameplate

If you want to sell 2,000 kVA transformer equipment, start with a sharp photo of the entire nameplate, not just the capacity field. We need the manufacturer, serial number, kVA or MVA rating, primary and secondary voltages, phase, frequency and impedance. Include the connection diagram and any separate accessory plates.

On liquid-filled equipment, capture the fluid type, fluid volume, total weight and cooling designation where listed. Tell us whether the fluid is mineral oil, FR3 natural ester or another documented type. PCB status must be disclosed and documented; a fluid label or an assumed manufacturing date should not replace available records. Existing test reports are useful, especially when they identify the same serial number.

05Dimensions, weight and site access matter at this size

There is no single footprint or shipping weight for a 2,000 kVA transformer. Voltage class, cooling design, enclosure, fluid and connection arrangement all affect dimensions and weight. Use the nameplate, outline drawing or manufacturer documentation when available. Measure the overall installed footprint, including radiators and projecting compartments, rather than only the main tank.

Tell us whether the equipment is outdoors on a pad, inside an electrical room or attached to switchgear. Gate widths, overhead obstructions, loading access and any documented lifting provisions affect pickup planning. We do not perform electrical disconnect work or ask sellers to drain fluid. Sellers use their own qualified electricians to de-energize and disconnect the equipment.

06What makes a 2 MVA unit useful to another project

This capacity can serve large plant loads, defined data center power blocks, and portions of solar or battery projects. Those applications do not all require the same transformer. A project may need a particular grounding arrangement, secondary voltage, impedance or connection interface, so “2 MVA” alone is not enough to establish a match.

We pay attention to complete documentation, intact accessories and a clearly described operating history. New-surplus equipment still needs storage and condition details; used equipment benefits from service records and available test data. Demand depends on the actual configuration and condition, not just the capacity label. We buy all brands, and failed or damaged units are reviewed case by case.

07Send the details needed for a written offer

Send nameplate and overall photos, location, quantity and condition notes through our equipment offer form. We review the information and may ask about PCB documentation, test data or access. If the equipment fits, our written offer spells out price, freight, loading and payment terms; pickup is scheduled with you, and payment follows those terms. See how the buying process works for details.

For a 2,000 kVA unit, include drawings and photos of connection points when available. Identify missing bushings, fans, gauges, doors or terminal components, and state whether it remains connected. We serve every region of Virginia and review equipment in neighboring states and nationwide on request.

Frequently asked questions

Is a 2 MVA transformer the same size as a 2,000 kVA transformer?

Yes, 2 MVA and 2,000 kVA express the same apparent-power rating. Still, check the complete nameplate for cooling-dependent ratings and winding details. A listing that says only “2 MVA” does not tell us the primary voltage, secondary voltage, impedance or whether that capacity requires fans.

Can I sell a 2,000 kVA transformer with a 480Y/277 secondary?

Yes, we buy 2,000 kVA three-phase transformers with a 480Y/277 secondary. Send the complete primary-voltage designation and connection details as well. We also need to know whether it is pad-mounted, close-coupled to switchgear or configured as a standalone substation transformer, because those arrangements affect its installation fit.

Do you buy 2,000 kVA transformers left over from solar or battery projects?

Yes, we buy new-surplus and used 2,000 kVA transformers from solar and battery projects. Include the winding voltages, connection diagram, impedance and any project-specific drawings. Tell us whether the unit was energized, how it was stored and whether accessories remain with it; project origin alone does not establish condition.

What if my transformer has multiple kVA ratings on its nameplate?

Send every listed rating and its associated cooling designation rather than choosing just the largest number. Multiple ratings may describe different cooling operating conditions. Include photos of installed fans and their controls if present, and identify missing components so we can understand which nameplate capacity corresponds to the equipment being sold.

Can you buy a 2,000 kVA unit still attached to secondary switchgear?

Yes, we buy unit substation transformers attached to secondary switchgear, but identify exactly what is included in the sale. Photograph the transformer nameplate, connection throat and overall assembly. Your qualified electrician handles de-energization and disconnection; we do not perform that work. Loading responsibilities are specified in the written offer.

Can I sell a failed 2,000 kVA oil-filled transformer?

Failed 2,000 kVA oil-filled transformers are reviewed case by case. Describe the failure, visible damage, leaks and any available test findings, and provide complete nameplate photos. PCB status must be disclosed and documented. Do not drain the fluid for us; explain the unit’s current condition and whether it has been disconnected.

Keep exploring

Directory

Transformer Sizes

Compare transformer sizes kVA, from 10 kVA single-phase to MVA-class units. Learn which nameplate details matter and send your equipment for an offer.

Size

2,500 kVA

Sell 2,500 kVA transformer equipment in Virginia. Send nameplate photos, voltage ratings and condition details for a written offer with clear terms.

Size

1,500 kVA

Sell 1,500 kVA transformer equipment in Virginia. Send nameplate photos, voltage ratings and condition details for review and a written offer if it fits.

Category

Three-phase pad-mount transformers

Virginia pad-mount transformers buyer for used and new-surplus three-phase units. Send nameplate photos, voltage details and condition notes for review.

Category

Unit substations

Need a unit substations buyer in Virginia? We buy transformer sections and review complete lineups. Send nameplates, section photos and access details.

Category

Substation transformers

Virginia substation transformers buyer for surplus and used units. Send nameplate photos, cooling ratings and condition details for a written offer.

Brand

McGraw-Edison

Sell McGraw-Edison transformer equipment in Virginia. We buy used and surplus units. Send nameplate photos and condition details for a written offer.

Brand

Cooper Power Systems

Sell Cooper Power Systems transformer equipment in Virginia. Send nameplate photos, ratings and condition details for a written offer on eligible units.

Guide

Transformer kVA and full-load amps chart

Use our transformer kVA and full-load amps chart to check ratings, compare single- and three-phase current, and identify your unit before selling.

Have a transformer to sell? Send us the nameplate photo.

Call or text (951) 403-5738 with photos, or use the short form. We reply with questions or a written offer.

(951) 403-5738