(951) 403-5738

We buy · Size

Sell 75 kVA Transformer Equipment in Virginia

Quick answerVirginia Transformer Buyers buys 75 kVA three-phase transformers, including dry-type and pad-mount units, from sellers across Virginia. To sell 75 kVA transformer equipment, send a readable nameplate photo, overall photos, location, quantity and condition notes. We buy used, surplus and new-surplus equipment; failed units receive case-by-case review. Voltage configuration, condition and loading access help determine whether a unit fits.
Ventilated dry-type transformer on a wooden pallet in a warehouse

A 75 kVA three-phase transformer often serves a building distribution load rather than an entire facility. You may find one supplying an office floor, school wing, small industrial load or a group of panels. A common indoor arrangement steps 480 V down to 208Y/120 V for receptacles, lighting and compatible three-phase equipment.

We buy this size in several configurations, but two units marked 75 kVA can serve very different applications. An indoor dry-type transformer is not interchangeable with a medium-voltage pad-mount simply because their ratings match. If you want to sell 75 kVA transformer equipment, start with the nameplate rather than the enclosure dimensions. Our transformer size pages help distinguish nearby ratings.

01What the 75 kVA three-phase rating means

A 75 kVA rating describes the transformer's rated apparent-power capacity under its specified operating conditions. On a three-phase nameplate, that is the total rating across all three phases, not 75 kVA per phase. It also does not mean the connected load continuously uses 75 kW; real power depends on power factor.

Current changes with voltage even though the kVA rating stays the same. For three-phase equipment, full-load line current is kVA × 1,000 ÷ (√3 × line-to-line volts). For example, a 75 kVA transformer at 208 V gives 75,000 ÷ (1.732 × 208), or approximately 208 A. Use the amp table on this page for other listed voltages, and see our kVA and full-load amps guide for context.

02Common voltage combinations at 75 kVA

For indoor building distribution, 480 V primary to 208Y/120 V secondary is a familiar configuration. The 208 V figure is the secondary line-to-line voltage; 120 V is line-to-neutral. We also buy 75 kVA units with other nameplate combinations, including 240 V or 480Y/277 V secondaries. The exact winding connection matters as much as the voltage numbers.

A three-phase pad-mount may instead have a medium-voltage primary, such as 12470GrdY/7200, and a low-voltage secondary such as 208Y/120. That primary designation describes grounded-wye system voltages; it should not be shortened to an ordinary 7,200 V three-phase configuration. Photograph the connection diagram, tap information and complete voltage markings so we can identify the equipment correctly.

  • Record primary and secondary voltages exactly as printed.
  • Include delta or wye markings and any neutral designation.
  • Show the available taps and the indicated tap position, if visible.
  • Photograph frequency, impedance and winding material when listed.

Full-load amps for a 75 kVA three-phase transformer

The amp table on this page uses the standard formula Amps = kVA × 1,000 ÷ (1.732 × line-to-line volts). Match the voltage on your nameplate to read the rated full-load current of each winding.

75 kVA three-phase full-load current
Winding voltageFull-load amps
208 V208
240 V180
480 V90.2
600 V72.2
2,400 V18
4,160 V10.4
12,470 V3.5
13,200 V3.3
13,800 V3.1
23,000 V1.9
34,500 V1.3

03Dry-type and pad-mount units need different details

We buy 75 kVA dry-type transformers from building replacements, equipment changes and surplus inventories. Useful details include copper or aluminum windings, temperature rise, insulation class and enclosure condition. Ventilated indoor units commonly have sheet-metal enclosures, but enclosure appearance alone does not establish the winding condition or suitability for outdoor use.

We also buy three-phase pad-mount transformers at this rating. For these units, show the tank, accessible exterior markings, bushings where safely visible, and any signs of leaks or damage. Fluid type, cooling designation and documented PCB status matter. Do not open energized compartments or drain fluid to prepare equipment for sale; PCB status must be disclosed and documented.

04Confirm 75 kVA on the actual nameplate

Look for a field labeled kVA, rated kVA or capacity, then confirm that the phase field identifies three-phase equipment. A nearby panel label or handwritten inventory tag is not a substitute for the transformer nameplate. Photograph the entire plate square-on, with enough detail to read the manufacturer, serial number, voltage ratings and connection diagram.

Do not round a neighboring rating to 75 kVA. A 45 kVA transformer and a 112.5 kVA transformer are distinct sizes with different capacities. If the plate lists multiple ratings tied to cooling or operating conditions, send the complete plate rather than selecting one number. If it is missing or unreadable, send any surviving labels and drawings without guessing.

05Physical size, weight and access affect the transaction

There is no single reliable dimension or weight for every 75 kVA transformer. Construction, voltage class, enclosure, winding material and fluid volume all affect the footprint and handling requirements. Use the manufacturer's listed weight when available, and send overall height, width and depth measurements if the unit must pass through a doorway or restricted route.

A dry-type unit on an office floor presents different access questions from a pad-mount beside a driveway. Tell us about stairs, elevators, door clearances, loading areas and whether the unit remains installed. Photos of the route are useful alongside equipment photos. We do not perform electrical disconnect work; sellers use their own qualified electricians to de-energize and disconnect equipment.

06What makes a 75 kVA transformer useful to another buyer

The 75 kVA size fits a recognizable range of smaller three-phase distribution applications, which makes the configuration important to resale demand. A 480-to-208Y/120 V dry-type unit serves a different need from a utility-voltage pad-mount. We pay attention to readable ratings, winding condition, completeness and whether the voltage arrangement matches another application. A common rating alone does not establish value.

Send a clear nameplate photo, overall photos, location, quantity and condition notes. We review the equipment and may ask about test data, PCB status or site access; if it fits, we send a written offer spelling out price, freight, loading and payment terms. Pickup is scheduled with you, and payment follows those terms. See how the buying process works for details.

Ready to sell 75 kVA transformer equipment? Submit the available information through our offer request form, including whether each unit is operating, disconnected, unused surplus or failed. We serve every region of Virginia and review equipment in neighboring states and nationwide on request.

Frequently asked questions

Will you buy a used 75 kVA 480-to-208Y/120 transformer?

Yes, we buy used 75 kVA three-phase transformers with 480 V primary and 208Y/120 V secondary ratings. Send the actual nameplate rather than relying on the panel it supplied. Include condition notes, whether it was operating before disconnection, and photos showing the enclosure and any visible damage.

Can I sell a 75 kVA transformer that was removed from a school?

Yes, we buy 75 kVA transformers removed from schools, including dry-type building distribution units. The former installation does not establish the equipment's condition or voltage configuration. Tell us why it was removed, whether it is stored indoors, and whether any covers, terminals or other components are missing.

Is a 75 kVA single-phase transformer the same as a three-phase unit?

No, a 75 kVA single-phase transformer is not the same equipment as a 75 kVA three-phase transformer. Both state apparent-power capacity, but their connections and applications differ. We buy both types, so photograph the phase field and connection diagram instead of identifying phase from the kVA rating alone.

Do copper windings guarantee a better offer for my 75 kVA transformer?

No, copper windings alone do not guarantee a better offer for a 75 kVA transformer. We buy copper- and aluminum-wound units and look at the complete equipment configuration. Voltage ratings, condition, missing components, documentation and freight or loading requirements also matter. Send the winding-material marking if the nameplate includes it.

Can you buy a 75 kVA pad-mount with an oil leak?

A leaking or damaged 75 kVA pad-mount receives case-by-case review. Disclose the leak and send photos taken from a safe location, along with fluid information and documented PCB status. Do not drain the transformer for sale. We do not provide environmental advice, and a review does not guarantee an offer.

What if my 75 kVA transformer has no recent test report?

You can submit a 75 kVA transformer without a recent test report. Send the nameplate, photos and an accurate description of its operating history and current condition. We may ask for available test data during review, but do not describe an untested unit as tested or assume that an intact enclosure proves electrical condition.

Keep exploring

Directory

Transformer Sizes

Compare transformer sizes kVA, from 10 kVA single-phase to MVA-class units. Learn which nameplate details matter and send your equipment for an offer.

Size

112.5 kVA

Sell 112.5 kVA transformer equipment in Virginia. We buy three-phase dry-type and pad-mount units. Send nameplate photos and condition notes for review.

Size

45 kVA

Sell 45 kVA transformer equipment in Virginia. We buy three-phase dry-type and pad-mount units. Send nameplate photos and condition details for an offer.

Category

Dry-type transformers

Need a dry-type transformers buyer? We buy ventilated, K-factor and drive isolation units across Virginia. Send nameplate photos for a written offer.

Category

Three-phase pad-mount transformers

Virginia pad-mount transformers buyer for used and new-surplus three-phase units. Send nameplate photos, voltage details and condition notes for review.

Brand

Howard Industries

Sell Howard Industries transformer equipment in Virginia. Send nameplate photos and condition details for a written offer with clear freight and payment terms.

Brand

RTE

Sell RTE transformer equipment in Virginia. We buy used and surplus pad-mount, substation and dry-type units. Send nameplate photos for review.

Guide

Transformer kVA and full-load amps chart

Use our transformer kVA and full-load amps chart to check ratings, compare single- and three-phase current, and identify your unit before selling.

Selling

Sell Your Transformer

Sell your transformers to Virginia Transformer Buyers. We buy used, surplus and decommissioned units. Send photos and nameplates for a written offer.

Have a transformer to sell? Send us the nameplate photo.

Call or text (951) 403-5738 with photos, or use the short form. We reply with questions or a written offer.

(951) 403-5738