Sell 20 MVA Transformer Equipment in Virginia

Quick answerTo sell 20 MVA transformer equipment, send Virginia Transformer Buyers a clear nameplate photo, overall photos, location, quantity and condition notes. We buy three-phase power and substation transformers of this size, including used, new-surplus and decommissioned units. We pay attention to voltage ratio, cooling ratings, condition and transport requirements; failed units are reviewed case by case.
Rear view of a flatbed trailer hauling a substation transformer with fan-cooled radiators

A 20 MVA transformer is substantial three-phase equipment, often connected with utility substations, data center campuses or generation step-up service. At this size, the voltage ratio and cooling designation matter as much as the headline rating. A unit rated 20 MVA with forced cooling is not the same operating proposition as one rated 20 MVA on natural cooling alone.

We buy equipment from sellers throughout Virginia, including transformers removed during substation upgrades, unused project purchases and retired generation equipment. Our power transformer buying page covers the broader equipment category; this page focuses on the nameplate, operating history and handling details that matter for a 20 MVA unit.

01What the 20 MVA rating actually means

Twenty MVA equals 20,000 kVA of apparent power. It describes the transformer's rated capacity under specified operating conditions, not its physical dimensions or a guaranteed amount of usable real power. Real power in megawatts depends on load power factor, while permissible loading also depends on cooling, temperature limits and operating conditions.

Check whether 20 MVA is the base rating or the highest rating in a cooling sequence. A plate showing 12/16/20 MVA identifies different capacity levels associated with its stated cooling stages. For oil-filled equipment, ONAN denotes natural oil and natural air cooling; ONAF adds forced air cooling. Send the full rating sequence rather than describing the unit only by its largest number.

The amp table on this page helps relate capacity to line voltage. For three-phase equipment, full-load current is I = VA ÷ (√3 × line-to-line volts). As one example, 20,000,000 VA ÷ (√3 × 138,000 V) is approximately 83.7 A. Our kVA and full-load amps guide explains the relationship.

02Voltage combinations and service applications

Twenty-MVA units do not have one standard voltage combination. Examples you may encounter include 69 kV to 13.8 kV, 138 kV to 13.8 kV and 34.5 kV to 13.8 kV. Generation step-up units may connect a generator-voltage winding to a higher-voltage system. These are examples, not interchangeable specifications; the actual nameplate controls.

For utility substation service, we pay attention to winding connections, insulation levels and tap-changing equipment. For a data center campus, a 20 MVA transformer may feed medium-voltage distribution rather than deliver 480Y/277 V directly. For generation service, the generator-side voltage and winding arrangement help distinguish the unit from a distribution-oriented transformer.

Include details about a load tap changer or de-energized tap changer, including its range and condition when known. A voltage description alone can leave out important differences in grounding and connections. Our substation transformer page covers equipment used in these installations.

Full-load amps for a 20 MVA three-phase transformer

The amp table on this page uses the standard formula Amps = kVA × 1,000 ÷ (1.732 × line-to-line volts). Match the voltage on your nameplate to read the rated full-load current of each winding.

20 MVA three-phase full-load current
Winding voltageFull-load amps
208 V55,514
240 V48,113
480 V24,056
600 V19,245
2,400 V4,811
4,160 V2,776
12,470 V926
13,200 V875
13,800 V837
23,000 V502
34,500 V335

03Confirm 20 MVA from the complete nameplate

Photograph the whole nameplate straight on, with enough resolution to read the smaller fields. Look for 20 MVA, 20,000 kVA or a multi-stage rating ending at that capacity. Confirm the three-phase designation and frequency, and capture both winding voltages rather than relying on a site inventory label.

We also need the manufacturer, serial number, cooling class, impedance, winding connections and listed weights. Photograph separate plates for the tap changer and accessories if present. If the equipment lists IEEE C57 standards, preserve those markings in the photo along with temperature-rise and insulation information.

An asset described locally as a '20-meg transformer' may carry a different base rating or have been grouped with other equipment in a project schedule. If the plate shows a different capacity, our transformer size directory helps identify the appropriate category. Do not substitute an estimated capacity for a readable plate.

04Physical size, weight and transport details

There is no reliable universal weight or footprint for a 20 MVA transformer. Voltage class, insulation design, fluid volume, cooling equipment and construction all affect its dimensions and mass. A higher-voltage unit may have significant bushing clearances, while radiators, conservators and attached cabinets can extend beyond the main tank.

Send available drawings showing overall dimensions, shipping dimensions, total weight and transport weight. Note whether radiators, bushings or other components are installed, removed or stored separately. A shipping weight may exclude fluid or accessories, so it should not be treated as the complete operating weight without checking the drawing notes.

Photograph the route from the transformer to the loading area, including gates, overhead obstructions and nearby structures. Tell us whether it remains on a foundation or is already in storage. We do not perform electrical disconnect work or ask sellers to drain fluid; use your qualified electricians to de-energize and disconnect the equipment.

05What affects demand for a 20 MVA transformer

Demand for a particular 20 MVA unit depends on whether its specifications fit another installation. Capacity alone does not establish suitability. Voltage ratio, frequency, impedance, winding arrangement, cooling capability and tap range can narrow or broaden the available applications.

We buy used, new-surplus and decommissioned units of all brands, but we need to understand what accompanies the transformer. Complete radiators, bushings, fans, control cabinets and tap-changing equipment give a clearer picture than a main tank alone. Tell us about missing components, leaks, storage conditions or known operating problems.

Available maintenance records and test reports help explain condition without replacing the nameplate information. Identify mineral oil or FR3 natural ester when documented, and disclose and document PCB status. We are an independent buyer, not affiliated with any manufacturer, including Virginia Transformer Corp of Roanoke.

06What to send for a 20 MVA transformer offer

When you are ready to sell 20 MVA transformer equipment, send clear nameplate and overall photos, its location, quantity and condition notes through the offer form. We review the information and may ask about PCB documentation, test data or site access. If the equipment fits, we send a written offer specifying price, freight, loading and payment terms, then schedule pickup with you; payment follows those terms. See how the buying process works for details.

For this size, include the cooling-stage ratings, accessory inventory, weight information and whether the unit is still connected. If several transformers are available, label each photo set by serial number. Distinguishing installed units from stored spares helps keep the equipment description and handling requirements clear.

Frequently asked questions

Does a 12/16/20 MVA transformer qualify as a 20 MVA unit?

Yes, its highest listed rating is 20 MVA, but the complete cooling sequence must be identified. That capacity depends on the cooling stage and conditions stated on the nameplate. Send photos showing all ratings and tell us whether the fans, controls and other cooling components are present and operational.

Can I sell a 20 MVA generation step-up transformer?

Yes, we buy 20 MVA generation step-up transformers. Send the generator-side and system-side voltages, winding connections, cooling ratings and condition information. Include any available drawings and records identifying the installation. We need the actual nameplate specifications, not just the generator's megawatt rating, to describe the transformer correctly.

Will you buy a 20 MVA transformer with removed radiators?

Yes, we buy 20 MVA transformers with radiators removed, with the equipment's completeness and condition clearly described. Photograph the tank connections and each stored radiator group. Identify missing parts and explain storage conditions. Do not assume that a transport configuration represents everything included with the sale.

Can you review a failed 20 MVA power transformer?

Failed 20 MVA power transformers are reviewed case by case. Describe the failure, known damage and any available diagnostic findings. Include photos of affected bushings, the tank and accessories where safely accessible. PCB status must be disclosed and documented; do not drain fluid or disturb damaged electrical components for photos.

Does a 20 MVA nameplate mean the transformer supplies 20 MW?

No, a 20 MVA nameplate specifies apparent power, not a fixed 20 MW output. Real power depends on power factor, and operating limits still depend on the transformer's ratings and conditions. For a sale, provide the MVA or kVA rating exactly as listed rather than converting it to an assumed megawatt capacity.

Do you need the operating weight or shipping weight?

Send both operating and shipping weights if they are available, with the drawing notes explaining what each includes. A transport configuration may exclude fluid, radiators, bushings or other components. Also provide dimensions and photos showing the present configuration so the written freight and loading terms can reflect the equipment being sold.

Keep exploring

Directory

Transformer Sizes

Compare transformer sizes kVA, from 10 kVA single-phase to MVA-class units. Learn which nameplate details matter and send your equipment for an offer.

Size

30 MVA and larger

Sell 30 MVA and larger transformer equipment to Virginia Transformer Buyers. Send nameplate photos, voltage ratings and site details for offer review.

Size

10 MVA

Sell 10 MVA transformer equipment in Virginia. We buy substation and power units. Send nameplate photos, voltage ratings and condition notes for review.

Category

Power transformers

Need a power transformers buyer? We buy surplus MVA-class, GSU and autotransformers. Send nameplate photos and site details for a written offer.

Category

Substation transformers

Virginia substation transformers buyer for surplus and used units. Send nameplate photos, cooling ratings and condition details for a written offer.

Brand

Howard Industries

Sell Howard Industries transformer equipment in Virginia. Send nameplate photos and condition details for a written offer with clear freight and payment terms.

Brand

Niagara Transformer

Sell Niagara Transformer transformer equipment in Virginia. Send nameplate photos and condition details for a written offer on used or surplus units.

Guide

Transformer kVA and full-load amps chart

Use our transformer kVA and full-load amps chart to check ratings, compare single- and three-phase current, and identify your unit before selling.

Selling

Sell Your Transformer

Sell your transformers to Virginia Transformer Buyers. We buy used, surplus and decommissioned units. Send photos and nameplates for a written offer.

Have a transformer to sell? Send us the nameplate photo.

Call or text (951) 403-5738 with photos, or use the short form. We reply with questions or a written offer.

(951) 403-5738